NSG430 Electrostatic Discharge Simulator:Rise Time: 5ns 30% at 2kVDischarge voltage: 2 - 16.5kVPolarity: positive / negative - non switchableDischarge capacitor Co: 150pF 10%Discharge resistor …
|
工厂翻新
要求信息
|
|
The Schaffner NSG600 Interference Simulator System provides for the simulation of the most varied transient conditions which occur in AC and DC mains, but also …
|
工厂翻新
要求信息
|
|
The NSG 200D ESD Mainframe (shown here with NSG222A) contains all the fundamental components such as the power supplies, switches, filters and safety devices that …
|
工厂翻新
要求信息
|
|
Schaffner NSG 222A Fast Impulse Plug-In
Produces fast interference pulses typical to mechanical devices such as relays, switches etc. Pulse amplitude 50 to 2500V,
rise time 5 …
|
工厂翻新
要求信息
|
|
The NSG222 Interference Generator Plug-In produces fast interference pulses typical of those produced by mechanical devices such as switches, relays, etc. The pulses produced have …
|
工厂翻新
要求信息
|
|
LINE IMPEDANCE STABILIZATION NETWORK Delta LISN for Telecom, 2A, 150 Ohm
|
新的
要求信息
|
|
PMMEP-330 Isotropic E-Field Sensor 100 kHz-3 GHz, 300 V/m. Sensitivity: 0.3 V/m, traceable calibration. Requires OR-03.
|
工厂翻新
要求信息
|
|
PMMEP-408 Isotropic E-Field Sensor 1 MHz - 40 GHz, 800 V/m. Sensitivity: 0.8 V/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMMHP-102 Isotropic H-Field Sensor 30 MHz - 1 GHz, 20 mA/m - 20 A/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMMEP-301 Isotropic E-Field Sensor 100 kHz-3 GHz, 1000 V/m. Sensitivity: 1 V/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMMHP-050 Isotropic H-Field Sensor 10 Hz - 5 kHz, 10 nT - 40 uT, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMMHP-051
HP051 Magnetic Field Sensor for PMM 8055 and PMM 8053. The PMM HP051 is a new magnetic field sensor in the 10 Hz - …
|
新的
要求信息
|
|
Programmable optical repeater. Fiber optic, battery charger and optical converter included.
The PMM OR-03 is a programmable optical repeater that allows the connection of every …
|
新的
要求信息
|
|
Discontinued in 2016 and replaced by the NNB 52. LINE IMPEDANCE STABILIZATION NETWORK CISPR-16/22 Four Line 3-Phase LISN 32A, 50 Ohm // (5 Ohm+50 mH). …
|
工厂翻新
要求信息
|
|
LINE IMPEDANCE STABILIZATION NETWORK CISPR-16/22 Four Line 3-Phase LISN 64A, 50 Ohm // (5 Ohm+50 mH). 9 kHz-30 MHz
|
新的
要求信息
|
|
PMM1008-01 Current generator according to IEC/EN 61000-4-8, up to 160A continuous, 1200A short-term (5 sec. max.). Output voltage maximum 4Vrms. Internal timer and RS-232 interface. …
|
新的
要求信息
|
|
ISO7637-2 LISN 100 A
|
新的
要求信息
|
|
ISO7637-2 LISN 70 A
|
新的
要求信息
|
|
PMM1008-02 1m Square loop antenna, mast included.
The PMM 1008 is an integrated system for magnetic field immunity test according to IEC 1000-4-8 & …
|
新的
要求信息
|
|
PMM1008-03 1.5m Square loop antenna, mast included.
The PMM 1008 is an integrated system for magnetic field immunity test according to IEC 1000-4-8 & …
|
新的
要求信息
|
|
ISO7637-2 LISN 50 A
|
新的
要求信息
|
|
PMM1008-04 2m Square loop antenna, mast included. Max continuous field 435A/m.
The PMM 1008 is an integrated system for magnetic field immunity test according …
|
新的
要求信息
|
|
Magnetic immunity test system
The PMM 1008 is an integrated system for magnetic field immunity test according to IEC 1000-4-8 & EN 61000-4-8.
The system is composed …
|
新的
要求信息
|
|
PMMEP-105 Isotropic E-Field Sensor 100 kHz - 1 GHz, 50 V/m. Sensitivity: 0.05 V/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMMEP-183 Isotropic E-Field Sensor 1 MHz - 18 GHz, 800 V/m. Sensitivity: 0.8 V/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMM EP-300 High sensitivity Isotropic E-Field Sensor 100 kHz - 3 GHz, 300 V/m. Sensitivity: 0.1 V/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
LINE IMPEDANCE STABILIZATION NETWORK CISPR-16 One Line Single Phase LISN 150A, 50 Ohm//(1 Ohm+5 mH)
|
新的
要求信息
|
|
LINE IMPEDANCE STABILIZATION NETWORK CISPR-16/22 Four Line 3-Phase LISN 100A, 50 Ohm // (5 Ohm+50 mH). 9 kHz-30 MHz
MAIN FEATURES
…
|
新的
要求信息
|
|
PMMHP-032 Isotropic H-Field Sensor 100 kHz - 30 MHz, 20 mA/m - 20 A/m, traceable calibration. Requires OR-03.
|
新的
要求信息
|
|
PMMEP-600 Isotropic E-Field Probe 100 kHz-6 GHz, 90 V/m. Sensitivity: 0.3 V/m. Full calibration. Includes optical to serial and USB to serial adapters and 10m …
|
新的
要求信息
|